Do you have a question about the Procentec ComBricks and is the answer not in the manual?
Explains the segmentation and modularity of PROFIBUS repeaters.
Describes remote network monitoring using ProfiTrace OE via web browser.
Step-by-step guide for rapid initial setup and operation of ComBricks.
Instructions on how to change the default IP address of the Head Station.
Procedure for verifying ProfiTrace OE functionality on the PROFIBUS installation.
Guidance on attaching and detaching backplane units to DIN-rail.
Steps for properly installing various modules into the ComBricks backplane slots.
Instructions for connecting Ethernet cables to the Head Station for network access.
Details on connecting the 24 VDC power supply to the Head Station.
Guide to setting up repeater modules using dipswitches or web server.
Overview of the current state of installed modules and system information.
Configuration settings for time synchronization, display, and language.
Setting up network names and assigning repeater modules to networks.
Configuring network settings like IP address, subnet mask, and gateway.
Procedures for setting user and administrator passwords and access rights.
Display of all available devices and their status in the network.
Setting up events for email alerts and logging within the network.
Viewing captured signal quality data from SCOPE repeater modules.
Information on using the SD card for data storage, logs, and settings.
Explanation of the status indicators (LEDs) on the Head Station.
Details on setting up redundant connections with the RS-485-IS Barrier module.
Specific considerations for using fiber optic modules in redundant setups.
Configuring critical event alarms for fiber optic connections.
Steps for configuring the PBS-001 module for PROFIBUS DP Slave operation.
Configuring the PBS-001 module for network coupling and data transfer.
Steps for quick setup and usage of the PA module in Link or Coupler mode.
Enabling and using PA modules for network monitoring and alarming.
Using the PA module in Link mode for PROFIBUS PA integration.
Including the PND-001 module in PLC projects for remote I/O.
Configuring the PND-001 module for network coupling or proxy functions.
Steps for integrating CommDTM with FDT managers for asset management.
Steps to enable and configure the OPC server for data access.
Procedure for updating the firmware on the ComBricks Head Station.
Steps for updating firmware on individual ComBricks modules.
Technical details for the oscilloscope function of RS-485-IS Barrier.
Specifications for the PROFIBUS Slave Module PBS-001 as a DP slave.
Remarks and order code for Head Station Type 1C product.
Remarks and order code for Head Station Type 1B product.
Remarks and order code for Head Station Type 1A product.