SERVICE PROGRAM TABLES
B132/B200 5-78 SM
2891 Sp3:FC:LL Special Paper 3: FC Low
2892 Sp3:FC:ML Special Paper 3: FC Medium Low
2893 Sp3:FC:MM Special Paper 3: FC Medium
These SPs set the paper size correction coefficient for the image to paper transfer
bias threshold values calculated based on the reading of the absolute humidity from
the temperature/humidity sensor and the thresholds set with SP2304.
SP2891 – Up to SP2304 001: Threshold 1
SP2892 – More than SP2304 001 Threshold 1, up to SP23204 002 Threshold 2.
SP2893 – More than SP2304 002 Threshold 2, up to SP2304 003 Threshold 3.
SP2894 – More than 2304 003 Threshold 3, up to SP2304 004 Threshold 4.
SP2895 – More than 2304 004 Threshold 4
These settings apply only to the image area printed on Special Paper 3 in full-color
mode.
2891 2892 2893
017 Side1:PTR [10~250/5%] [10~250/5%]
018 Side1:SepDC [10~250/5%]
019 Side1:SepAC
[10~250/5%]
[10~250/5%]
027 Side2:PTR [10~250/5%]
028 Side2:SepDC [10~250/5%]
029 Side2:SepAC
[10~250/5%]
[10~250/5%]
2894 Sp3:FC:MH Special Paper 3: FC Medium High
2895 Sp3:FC:HH Special Paper 3: FC High
2894 2895
017 Side1:PTR [10~250/5%] [10~250/5%]
018 Side1:SepDC [10~250/5%] [10~250/5%]
019 Side1:SepAC [10~250/5%] [10~250/5%]
027 Side2:PTR [10~250/5%]
028 Side2:SepDC
029 Side2:SepAC
[10~250/5%]
2901 Disp T/H Sn:K_PCU Temperature/Humidity Sensor: PCU
This SPs display the the temperature (oC) and humidity (both relative and absolute)
readings of the temperature and humidity sensor located at the black PCU on the
right side of the machine. These readings are updated every 60 sec.
• 001~004 display the current readings.
• 005~008 display the previous readings.
001 Temp Disp 005 Temp:Prev Range: 0~100/1 deg.
002 Rel Humidity Disp 006 Rel Humid:Prev Range: 0~100/1% RH.
003 Abs Humidity Disp 007 Abs Humid:Prev Range: 0~1000 g/m
3
004 Env Disp:Current 008 Env Disp:Prev
2902 Set Temp: K_PCU Set Temperature: PCU: Forced Setting
Use these settings to turn off the temperature/humidity sensor, or set its level of
detection.
[0~5/1]
0: Sensor Detect 3 MM:
1: LL 4MH:
2: ML 5 HH: