5-1
Service
Tables
21 August 2006
SERVICE PROGRAM MODE
1. Press the Tools button.
NOTE: Insert interlock cheater if +UNREG (voltage for mo-
tors) is needed.
2. With the Arrow key, select Service access and press the OK
button.
3. Key in password:
107 (using the Arrow and Change button).
4. Press the OK button.
5. Switch off the main power to exit the Service mode or press
the ESC button to exit the Service mode and enter the op-
erator mode.
Exit
1. Make sure the main power is switched off.
NOTE: Insert interlock cheater if +UNREG (voltage for mo-
tors) is needed.
2. Press and hold the left hand button on the Control Panel.
3. Switch on the main power switch.
4. Release the button on the Control Panel.
NOTE: When entering the SP mode this way, the ma-
chine will reset the password to the default value 107.
5. Key in password:
107 (using the Arrow and Change button)
6. Press the OK button.
7. Switch off the main power to exit the Service mode or press
the ESC button to exit the Service mode and enter the op-
erator mode.
Exit
CAUTION
Never turn off the main power when motors are cycling. To avoid damaging
the circuitry, stop the motor/motors running under the Check Motors menu,
and then switch the main power off.
5.1 SERVICE PROGRAM MODE
5.1.1 SERVICE PROGRAM MODE OPERATIONS
The Service Program (SP) mode is used to check electrical data, check electrical
components and adjust values. One service program mode is provided and controlled
from the UI (User Interface) on the booklet maker. Peripheral units are embedded
in this service program. Where applicable, a sub menu appears after a function is
selected listing the peripherals.
Entering and Exiting the SP mode
There are two ways to enter the service mode either from the operator mode ( )
or directly from switched off machine ( ).
5. SERVICE TABLES