Service Call Conditions
D129/D130 6-34 SM
-52 -
Finisher folder plate motor error
The folder plate moves but is not detected at the home position within the
specified time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Folder plate HP sensor disconnected, defective
Folder plate motor disconnected, defective
Folder plate motor overloaded due to obstruction.
-53 -
Folding unit bottom fence lift motor
The folding unit bottom fence movement is not finished within a certain time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Motor harness loose, broken
Motor drive obstructed
Motor defective
-55 -
Clamp roller retraction motor error
The clamp roller movement is not finished within a certain time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Motor harness loose, broken
Motor drive obstructed
Motor defective
-57 -
Stack junction gate motor error
The stack junction gate motor moves but the stack junction gate is not
detected at its position within a specific time.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
Motor broken
Motor connection loose
Motor overloaded