Service
Program
Mode Tables
006
Lc (Off Timing): Special 1 [-20 to 20 / -5 / 1 mm]
Adjust the timing to turn off the transfer current for the image area (Special
1).
007
La (On Timing): Special 2 [-20 to 20 / 0 / 1 mm]
Adjust the timing to turn on the transfer current for the leading edge (Special
2).
008
Lb (Switch Timing): Special 2 [0 to 30 / 10 / 1 mm]
Adjust the timing to switch transfer current from the leading edge to the
image area (Special 2).
009
Lc (Off Timing): Special 2 [-20 to 20 / -5 / 1 mm]
Adjust the timing to turn off the transfer current for the image area (Special
2).
010
La (On Timing): Special 3 [-20 to 20 / 0 / 1 mm]
Adjust the timing to turn on the transfer current for the leading edge (Special
2).
011
Lb (Switch Timing): Special 3 [0 to 30 / 10 / 1 mm]
Adjust the timing to switch transfer current from the leading edge to the
image area (Special 2).
012
Lc (Off Timing): Special 3 [-20 to 20 / -5 / 1 mm]
Adjust the timing to turn off the transfer current for the image area (Special
2).
2912* Transfer Reverse Rotation
002
Interval [0 to 10 / 3 / 1 ]
Sets the reverse time of the transfer/development motor after the end of a
job.