System SP Tables-2
D129/D130 3-36 SM Appendix
2812* Drum Reverse Rotation (SSP)
001
Reverse time [0 to 9 / 4 / 1 ]
Sets the reverse time of the drum motor after the end of a job.
002
Interval time [0 to 19 / 9 /1 ]
Sets the waiting time of the drum motor reverse after the end of a job.
2911* Transfer Current On/Off Timing (SSP)
001
La (On Timing) [-20 to 20 / 0 / 1 mm]
Adjust the timing to turn on the transfer current for the leading edge.
002
Lb (Switch Timing) [0 to 30 / 10 / 1 mm]
Adjust the timing to switch transfer current from the leading edge to the
image area.
003
Lc (Off Timing) [-20 to 20 / -5 / 1 mm]
Adjust the timing to turn off the transfer current for the image area.
004
La (On Timing): Special 1 [-20 to 20 / 0 / 1 mm]
Adjust the timing to turn on the transfer current for the leading edge (Special
1).
005
Lb (Switch Timing): Special 1 [0 to 30 / 10 / 1 mm]
Adjust the timing to switch transfer current from the leading edge to the
image area (Special 1).