Service
Program
Mode Tables
2802*
TD Sensor Manual Setting
Allows you to adjust the TD sensor output manually for the following.
001
VTS [1 to 5 / 4.78 / 0.01vol ]
Adjusts the TD sensor output (VT).
Change this value after replacing the development unit with another one
that already contains toner. For example, when using a development unit
from another machine for test purposes. To adjust VT, use a similar
procedure as for SP2-220.
002
VTMAX [1 to 5 / 4.78 / 0.01vol ]
Adjusts the maximum value for SP2802 1.
003
VTMIN [1 to 5 / 1 / 0.01vol ]
Adjusts the minimum value for SP2802 1.
2805
Process Setting
Performs the developer initialization. Press "Execute" to start. This SP
should be performed after doing SP2801 at installation and after replacing
the drum.
2810
Grayscale Setting
Initializes the LD power setting. This SP should be done after replacing the
drum.