Service Call
M160/M161 6-14 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC532-00 D
PSU Cooling fan error
The fan motor lock (rotating state) signal is sampled at 100 ms
intervals and the machine fails to receive the lock signal 50
times in succession.
Failed fan motor
Disconnected connector
Replace the fan motor.
Check the connector.
Replace the harness.
Replace the IOB.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC541-00 A
Broken fusing (Center) thermistor wire
The condition whereby the temperature is -20 deg C or less for 5
seconds has been detected 10 times or more.
Broken thermistor wire
Bad connector contact
Clear the SP: fusing SC.
Check the connector connection.
Replace the fusing (Center) thermistor.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC542-01 A
Fusing lamp (Center) thermistor not reloaded 1
The heater thermistor has increased by less than 2.0 degrees in
1.5 seconds 5 times in a row.
Deformed or floating thermistor
Input voltage out of range
Clear the SP: fusing SC.
Replace the thermistor.