Service Call
M160/M161 6-30 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
Case 1
Engine board does not start up.
Case 2
Engine board reset unexpectedly.
Check the connection between the engine board and the
controller board.
If this problem always occurs, replace the engine board. If
the problem persists, consider replacing the controller board
or other boards between them.
If this problem occasionally occurs, multiple causes are to
be considered, such as the software, engine board,
controller board, and PSU.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC672-10 D
Controller start up error
The controller and control panel failed to establish
communication when the power was turned on.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector is loose, broken, or defective
Controller's late response
Turn the main power off/on.
Check the connection of the controller board.
Replace the controller board.
Check the control panel harness.