SC No. Level Error Name/Error Condition/Major Cause/Solution
SC672-11 D
Controller start up error
After the machine was powered on, communication between the
controller and the operation panel was not established, or data
transmission failed after a normal startup.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector is loose, broken, or defective
Controller's late response
Turn the main power off/on.
Check the connection of the controller board.
Replace the controller board.
Check the control panel harness.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC672-12 D
Controller start up error
Communication with controller was interrupted after a normal
startup.
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector is loose, broken, or defective
Controller's late response
Turn the main power off/on.
Check the connection of the controller board.
Replace the controller board.
Check the control panel harness.