Main SP Tables-2
M160/M161 3-20 SM Appendix
2927 [Initial Supply]
2-927-001 Initial Amount E*
[1 to 50 / 5 / 1g/step]
Target toner amount for supplying fixed
amount of toner when replacing.
2-927-002 Initial Mixing T E*
[0 to 300 / 10 / 1sec/step]
Idle time to mix for supplying fixed
amount of toner when replacing.
2-927-003 Ini-Coefficient E*
[0.0 to 5.0 / 1.5 / 0.1/step]
Coefficient for calcurating the amount of
toner supplying during printing after
toner cartridge is replaced.
2-927-004 Initial Flag E*
[0 or 1 / 0 / 1/step]
Information used to detect the
replacements and judge the upper limit.
2-927-005 Exchange Count E*
[0 to 1000 / 0 / 1count/step]
Counter for new toner detection.
2930 [Detection]
2-930-001 Cleaner Count E*
[1 to 20 / 5 / 1cycle/step]
Counter to rotate the cleaner parts
when remaining toner in the developer
detected.
2-930-002 stabilization T E*
[0.0 to 3.0 / 0.0 / 0.1sec/step]
Stability time of the sensor used for
detecting remaining toner in the
developer.
2-930-003 Upper n cycle E*
[0 to 20 / 1 / 1/step]
Upper counter to exclude from the
obtained result when toner remaining in
the developer detected.