Main SP Tables-5
M160/M161 3-82 SM Appendix
5491 [Optional Counter]
5-491-001
Detail Option C*
[0 or 1 / 00000000 / 1/step]
Determines whether to cancel the job
when MK1 keycard is pulled out from
the machine during job.
bit0: Forced Job Canceling
0: On. Cancels the job.
1: Off. Allows operation if MK1 keycard
is pulled out from the machine during
the job.
5501 [PM Alarm]
5-501-001
PM Alarm Level C*
[0 to 9999 / 0 / 1/step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1
to 9999) x 1000 > PM counter
5-501-002
Original Count Alarm C*
[0 or 1 / 0 / 1/step]
0: No alarm sounds
1: Alarm sounds after the number of
originals passing through the ADF >
10,000
5504 [Jam Alarm]
5-504-001
- C*
[0 to 3 / 3 / 1/step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Sets the alarm to sound for the
specified jam level (document misfeeds
are not included).