SP Mode Tables
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a
set number of copied sheets (for example, default 700 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
5-505-001
- C*
[0 to 255 / 15 / 1hundred/step]
0: Alarm Off
5507
[Supply/CC Alarm]
Enables or disables the notifying a supply call via the @Remote.
5-507-001 Paper Supply Alarm C*
[0 or 1 / 0 / 1/step]
Switches the control call on/off for the
paper supply. DFU
0: No alarm
1: Sets the alarm to sound for the
specified number transfer sheets for
each paper size (A3, A4, B4, B5, DLT,
LG, LT, HLT)
5-507-003 Toner Supply Alarm C*
[0 or 1 / 1 / 1/step]
Switches the control call on/off for the
stapler installed in the finisher. DFU
If you select "1" the alarm will sound
when the copier detects toner end.
0: Off
1: On
5-507-004 MaintenanceKIt C*
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
5-507-005 DrumLifeRermain C*
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
5-507-006
Toner Collection Bottle
Alarm
C*
[0 or 1 / 1 / 1/step]
0: OFF
1: ON