Main SP Tables-5
M160/M161 3-84 SM Appendix
5-507-080 Toner Call Timing C*
[0 or 1 / 0 / 1/step]
0: At replacement
1: AtLessThanThresh
Changes the timing of the "Toner Supply
Call" via the @Remote, when the
following conditions occur.
5-507-081 Toner Call Threshold C* [10 or 90 / 10 / 10%/step]
5-507-128 Interval: Others C*
[250 to 10000 / 1000 / 1page/step]
The "Paper Supply Call Level: nn" SPs
specify the paper control call interval for
the referenced paper sizes. DFU
5-507-133 Interval: A4 C*
5-507-134 Interval: A5 C*
5-507-142 Interval: B5 C*
5-507-164 Interval: LG C*
5-507-166 Interval: LT C*
5-507-172 Interval: HLT C*
5508 [CC Call]
5-508-001
Jam Detection: Time Length C*
[3 to 30 / 10 / 1min./step]
Sets the length of time to determine
paper jams required to initiate a call.
5-508-012
Jam Detection: Continuous
Count
C*
[2 to 10 / 5 / 1time/step]
Sets the number of continuous paper
jams required to initiate a call.
5-508-013
Door Open: Time Length C*
[3 to 30 / 10 / 1min./step]
Sets the length of time the door remains
open before the machine initiates a call.