SP Mode Tables
1001 [Bit Switch]
009 Bit Switch 9 Settings 0 1
bit 0 PDL Auto Detection timeout of jobs
submitted via USB or Parallel Port (IEEE
1284).
Disabled
(Immediately)
Enabled
(10 seconds)
To be used if PDL auto-detection fails. A failure of PDL autodetection doesn't
necessarily mean that the job can't be printed. This bit switch tells the device
whether to time-out immediately (default) upon failure or to wait 10 seconds.
bit 1 DFU - -
bit 2 Job Cancel Disabled
(Not
cancelled)
Enabled
(Cancelled)
If this bit switch, all jobs will be cancelled after a jam occurs.
Note: If this bitsw is enabled, printing under the following conditions might
result in problems:
- Job submission via USB or Parallel Port
- Spool printing (WIM >Configuration > Device Settings > System)
bit 3 DFU - -
bit 4 Timing of the PJL Status ReadBack (JOB
END) when printing multiple collated
copies.
Disable Enable
This switch determines the timing of the PJL USTATUS JOB END sent when
multiple collated copies are being printed.
0 (default): JOB END is sent by the device to the client after the first copy has
completed printing. This causes the page counter to be incremented after the
first copy and then again at the end of the job.
1: JOB END is sent by the device to the client after the last copy has finished
printing. This causes the page counter to be incremented at the end of each
job.
bit 5 Display UTF-8 text in the operation panel Enabled Disabled