Bit Switches - 3
M160/M161 Fax Option 85 SM
M160/M161 FAX
OPTION
Communication Switch 11Not used (Do not change the factory settings.)
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-7
Memory transmission: Interval
between dialing attempts to the
same destination.
01FF (Hex) minutes
Communication Switch 13Not used (Do not change the factory settings.)
Communication Switch 14 (SP No. 1-104-021)
No Function Comments
0
Inch-to-mm conversion during
transmission
0: Disabled, 1: Enabled
0: In immediate transmission, data scanned in
inch format are transmitted without conversion.
In memory transmission, data stored in the
SAF memory in mm format are transmitted
without conversion.
Note: When storing the scanned data into SAF
memory, the fax unit always converts the data
into mm format.
1: The machine converts the scanned data or
stored data in the SAF memory to the format
which was specified in the set-up protocol
(DIS/NSF) before transmission.
6-7
Available unit of resolution in
which fax messages are
received
For the best performance, do not change the
factory settings.
The setting determined by these bits is
informed to the transmitting terminal in the
pre-message protocol exchange (in the
DIS/NSF frames).
Bit 7 Bit 6 Unit
0 0 mm
0 1 inch
1 0 mm and inch