Bit Switches - 6
M160/M161 Fax Option 105 SM
M160/M161 FAX
OPTION
IP Fax Switch 07 (SP No. 1-111-008)
No Function Comments
0
TSI information
0: Not added, 1: Added
Adds or does not add TSI information to
NSS(S).
1
DCN transmission setting at T1
timeout
0: Not transmitted
1: Transmitted
Transmits or does not transmit DCN at T1
timeout.
2 Not used Do not change this setting.
3
Hang up setting at DIS reception
disabled
0: No hang up
1: Hang up after transmitting DCN
Sets whether the machine disconnects
after DIS reception.
4
Number of times for training
0: 1 time, 1: 2 times
Selects the number of times training is
done at the same bit rate.
5
Space CSI transmission setting at
no CSI registration
0: Not transmitted
1: Transmitted
When "0" is selected, frame data is
enabled.
When "1" is selected, the transmitted data
is all spaces.