Bit Switches - 6
SM 106 M160/M161 Fax Option
IP Fax Switch 08 (SP No. 1-111-009)
No Function Comments
0-1
T1 timer adjustment
Adjusts the T1 timer.
The default is "00" (35 seconds).
Bit 1 Bit 0
0 0 35 s
0 1 40 s
1 0 50 s
1 1 60 s
2-3
T4 timer adjustment
Adjust the T4 timer.
The default is "00" (3 seconds).
Bit 3 Bit 2
0 0 3 s
0 1 3.5 s
1 0 4 s
1 1 5 s
4-5
T0 timer adjustment
Adjusts the fail safe timer. This timer sets
the interval between "setup" data
transmission and T.38 phase decision. If
your destination return is late on the
network or G3 fax return is late, adjust the
longer interval timer.
The default is "00" (75 seconds).
Bit 5 Bit 4
0 0 75 s
0 1 120 s
1 0 180 s
1 1 240 s