RIGOL 2 Command System
2-304 MSO2000A/DS2000A Programming Guide
:TRIGger:SHOLd:HTIMe
Syntax
:TRIGger:SHOLd:HTIMe <NR3>
:TRIGger:SHOLd:HTIMe?
Description
Set or query the hold time of setup/hold trigger.
Parameter
Name Type Range Default
<NR3> Real 2ns to 1s 50ns
Explanation
This command is available when the hold type (refer to the
:TRIGger:SHOLd:TYPe command) is set to
HOLd or SETHOLd.
Return Format
The query returns the hold time in scientific notation.
:TRIGger:SHOLd:PATTern
Syntax
:TRIGger:SHOLd:PATTern <pattern>
:TRIGger:SHOLd:PATTern?
Description
Set or query the data type of setup/hold trigger.
Parameter
Name Type Range Default
<pattern> Discrete {H|L} H
Return Format
The query returns the pattern currently set for each channel.