Stereo Modulation (Option R&S SML-B5) R&S®SML / R&S®SMV03
1090.3123.12 E-6 4.34
PRE
Des
cription: Sets one of various preemphasis options.
Command: PRE=x
Query: PRE?
Response: x
Value range: 0|1|2
0 = Off
1 = 50 Fs
2 = 75 Fs
Example: Command:
STEReo:DIRect “PRE=1“
The preemphasis is set to 50 Fs.
Query:
STEReo:DIRect? “PRE“
Response:
"1"
PRESET
Description: Sets the default settings in accordance with specifications.
Command: PRESET
Example: STEReo:DIRect “PRESET“
PS
Description: Sets or reads the program service (PS) name.
Command: PS = xxxxxxxx (char)
Query: PS?
Response: xxxxxxxx
Value range: 8 ASCII characters
Example: Command:
STEReo:DIRect “PS=RDS Test”
Sets the program service name to be transmitted to "RDS Test".
Query:
STEReo:DIRect? “PS“
Response:
"RDS Test"
Note: An eight-digit value must always be set. Blank spaces, if any, must also be entered,
otherwise the value will not be accepted.