Stereo Modulation (Option R&S SML-B5) R&S®SML / R&S®SMV03
1090.3123.12 E-6 4.36
RDS
Des
cription: RSwitches RDS on or off.
Command: RDS=x
Query: RDS?
Response: x
Value range: x = 0|1
Example: Command:
STEReo:DIRect “RDS=1“
RDS is switched on.
Query:
STEReo:DIRect? “RDS“
Response:
"1"
RDS-PH
Description: Sets the RDS phase.
Command: RDS-PH=xxx
Query: RDS-PH?
Response: xxx
Value range: 000 to 359 (ASCII coded decimal numbers)
Example: Command:
STEReo:DIRect “RDS-PH=100“
RThe RDS phase is set to 100 .
Query:
STEReo:DIRect? “RDS-PH“
Response:
"100"
RDS-DEV
Description: Sets the RDS frequency deviation (max. deviation).
Command: RDS-DEV=xxxx
Query: RDS-DEV?
Response: xxxx
Value range: 0000 to 1000 (ASCII coded decimal numbers), corresponding to 0 Hz to 10.00 kHz)
Example: Command:
STEReo:DIRect “RDS-DEV=0201“
The RDS frequency deviation is set to 2.01 kHz.
Query:
STEReo:DIRect? “RDS-DEV“
Response:
"0201"
Note: A four-digit value must always be set. Leading zeros, if any, must also be specified.