Stereo Modulation (Option R&S SML-B5) R&S®SML / R&S®SMV03
1090.3123.12 E-6 4.38
STATUS
Des
cription: Status request as to whether the encoder or the update loader program is being
executed.
Query: Status?
Response: xxx
Value range: ENC = encoder program is running
UPL = update loader program is running
Example: Query:
STEReo:DIRect? “STATUS
Response:
"ENC"
STORE
Description: Stores data in the flash memory. All RDS-specific settings are stored in data set
"x" of the flash memory.
Command: STORE=x
Value range: 1 to 5
Example: Command:
STEReo:DIRect “STORE=1“
The current settings are stored in data set "1".
TA
Description: Sets or reads the traffic announcement flag.
This flag signals whether traffic information is currently being broadcast.
Command: TA=x
Query: TA?
Response: x
Value range: 0|1
Example: Command:
STEReo:DIRect “TA=1“
The traffic announcement flag is set to "1".
Query:
STEReo:DIRect? “TA“
Response:
"1"