27—UTILITY Menu Parameters
370 www.RolandUS.com Roland VS-2400CD Owner’s Manual
DATE/TIME
To learn how to set the VS-2400CD’s calendar and clock that time-
stamp your recordings, see “Setting the VS-2400CD’s Clock” on
Page 65.
Parameter Initialization
Use the MIXER/UTILITY PARAMETER INITIALIZE screen to reset many of the
VS-2400CD’s mixer and/or UTILITY menu parameters to their default factory settings.
You may want to do this to start over with a clean slate, or if your VS-2400CD is
behaving oddly, and you suspect that some unknown parameter value may be the
cause.
Resetting Mixer and UTILITY Parameters
1. Press UTILITY.
2. Press PAGE until “PrmIni” appears above F6.
3. Press F6 (PrmIni).
4. Turn the Time/Value dial to select:
•
MIXER & UTILITY
—to initialize both the mixer and UTILITY parameters.
•
MIXER
—to initialize only the mixer parameters.
•
UTILITY
—to initialize only the UTILITY parameters.
5. Press F5 (OK)—a confirmation screen appears.
6. If you’re sure you want to proceed, press ENTER/YES. To cancel the operation,
press EXIT/NO.
This screen doesn’t initialize all mixer and/or UTILITY menu settings. Your basic
project settings remain, including your current IDE drive selection. Scenes, the tempo
map and sync track, LOCATOR/SCENE TYPE, SHIFT LOCK and NUMERICS TYPE
parameters are among the settings that aren’t initialized.
If this procedure doesn’t cure your VS-2400CD’s odd behavior, call Roland Product
Support at 323-890-3740, x3741.