Supplemental Information
446 www.RolandUS.com Roland VS-2400CD Owner’s Manual
CLOCK SOURCE
CLOCK SOURCE selects the master clock timing reference for the ADA-7000. This
parameter interacts with the VS-2400CD’s MASTER CLOCK parameter (Page 128).
• When the VS-2400CD’s MASTER CLOCK parameter’s value is R-BUS, the
ADA-7000’s CLOCK SOURCE should be set to INTERNAL or WORD CLOCK.
• When the VS-2400CD MASTER CLOCK is set to INT, DIGITAL IN or EXT TIME
CODE, the ADA-7000’s CLOCK SOURCE should be set to R-BUS.
The following table explains the CLOCK SOURCE values and tells you how to set the
VS-2400CD’s MASTER CLOCK parameter with each ADA-7000 CLOCK SOURCE
value.
SAMPLING FREQ
SAMPLING FREQ provides a readout of the sample rate at which the ADA-7000 is
operating and capturing audio through its input jacks. When the ADA-7000’s CLOCK
SOURCE parameter is set to INTERNAL, SAMPLING FREQ automatically switches to
the current project’s sample rate, unless the project uses the 88.2k or 64k sample
rates—the ADA-7000 doesn’t support the use of these two sample rates.
AE-7000 Settings
Turn down the volume for all connected equipment before changing the CLOCK
SOURCE value to avoid damage to your equipment.
If the ADA-7000
CLOCK SOURCE is:
This means that
the ADA-7000:
Set the VS-2400CD’s
MASTER CLOCK to:
INTERNAL uses its own master clock and sample
rate (see “SAMPLING FREQ” below).
R-BUS.
WORD CLOCK derives its clocking from the word
clock device connected to its rear-panel
WORD CLOCK jack.
R-BUS.
R-BUS derives master clock from the VS-2400CD. a clock source other
than R-BUS.
When the ADA-7000’s CLOCK SOURCE is set to any value other than INTERNAL, it
derives its sample rate from the selected master clock source.