EasyManuals Logo

Sakura Tissue-Tek Polar DM User Manual

Sakura Tissue-Tek Polar DM
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
c
Software version ................................................................................................................................ 1-52
Checking the Version.................................................................................................................... 1-52
Updating ....................................................................................................................................... 1-52
Chapter 2 Operating Method
Basic Operation Flow ................................................................................... 2-1
Logging On to the System ........................................................................... 2-2
Performing Pre-operation Checks ........................................................................................................ 2-2
Turning On the Power .......................................................................................................................... 2-2
Logging On to the Instrument ............................................................................................................... 2-3
Logging Off from the Instrument........................................................................................................... 2-3
Returning from the Sleep Mode ........................................................................................................... 2-3
Returning from the Standby Mode........................................................................................................ 2-3
Preparing for Sectioning .............................................................................. 2-4
Checking the Temperature Settings ..................................................................................................... 2-4
Checking the "FREE" Temperature Settings ........................................................................................ 2-4
Changing the Chamber Temperature ............................................................................................. 2-4
Changing the Specimen Head Temperature ................................................................................... 2-4
Using "Temperature Setting 1" or "Temperature Setting 2" .................................................................. 2-4
Preparing for Frozen Block Preparation ............................................................................................... 2-5
Freezing in the Chamber ...................................................................................................................... 2-5
Setting the Frozen Block on the Specimen Head ................................................................................. 2-6
Adjusting the Specimen Head .............................................................................................................. 2-7
Adjusting the Specimen Head Orientation (Angle).......................................................................... 2-7
Changing the Disposable Blade ........................................................................................................... 2-8
Using the High Profile Type ............................................................................................................ 2-8
Adjusting the Lateral Movement of the Blade Holder ..................................................................... 2-9
Using the Low Profile Type ........................................................................................................... 2-10
How to Set the Low Profile Adapter .............................................................................................. 2-10
Sectioning ..................................................................................................... 2-11
Preparing for Manual Sectioning (Final Shaving) ............................................................................... 2-11
Press the home position key to move the specimen head to the sectioning start position. .......... 2-11
Cutting the Specimen to Flat Surface (Rough Shaving) ............................................................... 2-11
Checking the Section Thickness for Sectioning (Final Shaving) ................................................ 2-11
Manually Sectioning the Specimen (Final Shaving) ........................................................................... 2-12
Sectioning Manually ........................................................................................................................... 2-12
Sectioning with the Anti-Roll Rake ..................................................................................................... 2-13
Sectioning with the Anti-Roll Plate...................................................................................................... 2-14
After Processing ......................................................................................... 2-15
Clean the Interior of the Chamber Using the Supplied Nozzle. .......................................................... 2-15
Performing Cleaning Operation .......................................................................................................... 2-16
Cancelling Cleaning Operation ..................................................................................................... 2-17
Defrosting Manually ........................................................................................................................... 2-18
Cancelling Manual Defrost Cycle ................................................................................................. 2-18
Performing Ozone Cycle Manually ..................................................................................................... 2-19
Cancelling Manual Ozone Cycle .................................................................................................. 2-19
Shutting Down the Instrument ............................................................................................................ 2-20
Shutting Down the Instrument Manually ............................................................................................. 2-20
Manual shutdown when "Always-on operation" is selected .......................................................... 2-20
Manual Shutdown under "Scheduled Operation".......................................................................... 2-21
Cancelling Manual Shutdown ....................................................................................................... 2-22
Shutting Down the Instrument Automatically ...................................................................................... 2-23
Cancelling Automatic Shutdown ................................................................................................... 2-24
Other Operations ........................................................................................ 2-25
When the Instrument Detects an Abnormality During the Ozone Disinfection Cycle .......................... 2-25
Errors notified after completion of ozone decomposition .............................................................. 2-25
Errors notified when ozone might still be inside the chamber ....................................................... 2-25

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sakura Tissue-Tek Polar DM and is the answer not in the manual?

Sakura Tissue-Tek Polar DM Specifications

General IconGeneral
BrandSakura
ModelTissue-Tek Polar DM
CategoryMedical Equipment
LanguageEnglish

Related product manuals