PR 5610 Installation Manual Commissioning with Terminal
Sartorius 143
5.7.3.2 Analog input / output module testing
The test can be executed for PR 1713/06 and PR 1713/07.
PR1713 Rel. 03.12 20.05.2004 09:05
Test PR1713/06 Slot-Number 2 Mo 06.May 2002 09:31:51
Current Analog Output Value: Dec: 75.0% = 15.000 mA (9FAD)
Enter decimal output 0..100%: _
Set Output:
D Decimal-Input-Format 0..100% for Output-Value
C Current-Input-Format 0.000..24.000 mA for Output-Value
E Exit
♦ Display of the socket number is in mask header:
Test PR 1713/06 Slot-Number 2
♦ Enter the analog output value
Entry of the analog output value is possible in two formats. Selection is by entry of the relevant letter.
• decimal entry 0…100%
D Decimal-Input-Format 0…100% for Output-Value
• current entry 0.000 - 24.000 mA
C Current-Input-Format 0.000 24.000 mA for Output-Value
The dialog line for decimal input is displayed as an example.
♦ Display of the actual analog output value is in the two formats. See line:
Current Analog Output Value
• decimal
Dec: 75.0%
• current
15.000 mA
♦ Leave mask 'Test PR 1713/06' with
E Exit
⇒ After leaving this mask (E), return is to the sub-menu
Test Inputs/Outputs:
The entered output values remain set, until returning to menu
Service
.
With PR 1713/07 additionally the analog-inputs are displayed:
PR1713 Rel. 03.12 20.05.2004 09:05
Test PR1713/07 Slot-Number 2 Mo 06.May 2002 09:31:51
Current Analog Output Value: Dec: 75.0% = 15.000 mA (9FAD)
Enter decimal output 0..100%: _
Analog Input 1 = 3072 = 75% = 3,75V Hex: BFF
Analog Input 2 = 3072 = 75% = 3,75V Hex: BFF
Analog Input 3 = 3072 = 75% = 3,75V Hex: BFF
Analog Input 4 = 3072 = 75% = 3,75V Hex: BFF
Set Output:
D Decimal-Input-Format 0..100% for Output-Value
C Current-Input-Format 0.000..24.000 mA for Output-Value
E Exit