Section 8: Appendix
HR2 Series Operator Manual Page 8-7
8.4 BASE REFERENCE POINT ADJUSTMENT (Cont’d)
8.4.3 Adjustment of Stop Position in Tear-off Mode (only for the first label)
Label stop position (first label) for Tear-off mode is adjustable within the range of +7.5mm to -7.5mm (+0.15"
to -0.15") due to the above settings on LCD screen
Notes
Adjustment of first label stop position is available only in Tear-off mode.
The above Tear-off position will be the stop position when the GAP sensor is selected.
Tear-off stop position will be adjusted if the criteria listed below are satisfied.
Power ON (when cover opened/closed just before powering off)
Cover open/close
Switching of sensor type (GAP<->I-MARK)
Changing of GAP sensor number
Adjustments
Stop position in Tear-off
mode
(only for first label)
Set up on LCD
Small pitch test print in Tear-
off mode: TEAR OFF TOP
POS
+3.75mm to -3.75mm
(+0.15" to -0.15")
Stop position for Dispense/
Tear - off mode
Set up on LCD
Adjustment mode: OFFSET/
Test Print mode: OFFSET
POSITION
+3.75mm to -3.75mm
(+0.15" to -0.15")
-7.5mm (-0.30")
Label feed direction
Base reference
point for printing
(Print head)
Adjustment for
“+” value
No
Adjustment
Adjustment for
“-” value
Tear-off
position
+7.5mm (+0.30")
28mm
(1.1")