Section 6: Basic Specifications
HR2 Series Operator Manual Page 6-1
BASIC SPECIFICATIONS
6.1 PRINTER BASIC SPECIFICATIONS
MODEL NAME
HR212 / HR224
PHYSICAL CHARACTERISTICS
Width 197 mm (7.75")
Height 285 mm (11.22")
Depth 365 mm (14.37")
Weight 16.4Kg (36.16 lbs.)
POWER SUPPLY
Input Voltage
Input power voltage: AC 100V - 240V, +/-10% (Full range)
Rated input voltage: AC 100V - 240V (Full range)
Power Consumption
HR212:
At peak: 95W / 95VA (Print ratio 30%)
In standby: 26W / 27VA
HR224:
At peak: 115W / 115VA (Print ratio 30%)
In standby: 26W / 27VA
ENVIRONMENTAL (EXCLUDING MEDIA)
Operating Temperature 0° to 40°C (32 to 104 F)
Storage Temperature -5° to 60°C (23 to 140 F)
Operating Humidity 10 to 80% RH, Non-condensing
Storage Humidity 10 to 90% RH, Non-condensing
PRINT
Method Thermal Transfer
Print Speed (selectable)
25 to 100 mm/sec (1 to 4"/sec)
(Setting value: 0.5"/sec increments)
*Print speed varies depending on the media used.
Resolution
HR212: 12 dots/mm (305 Dots Per Inch)
HR224: 24 dots/mm (609 Dots Per Inch)
Maximum Print Width 56 mm (2.2")
Maximum Print Length 200 mm (7.9")
Print darkness
Darkness range: A to B
Darkness level: 1 to 5