Section 2: Installation
Page 2-18 HR2 Series Operator Manual
2.6 BASIC CONNECTIONS (cont’d)
2.6.2 To Configure the Connected Interface
After connection, you need to set the configuration of the connected interface in the INTERFACE MODE
menu of the printer. Please refer to Section 3.7 Interface Mode for details on setting Interface Mode.
In Interface mode, you will need to determine which interface is set as Data Port and which is set as Sub Port.
An overview of each port is shown as below.
Data Port
When the interface is set to the Data Port, it can receive various SBPL commands and it can execute print
operations.
Data port selection: USB, LAN, RS-232C
* The interface which already set for SUB PORT is not able to select.
Sub Port
This port is for monitoring printer status and connecting to external devices.
Sub Port selection: NONE, USB, LAN, RS-232C
* The interface which already set for DATA PORT is not able to select.
Note:
Data Port and Sub Port cannot use the same interface at the same time.
2.6.3 Interface Combination
The interface combinations that can be used for Data Port and Sub Port are as follows.
[o: configurable, x: not configurable]
The following table shows the combination of interface with keypad and the port type.
[o: configurable, x: not configurable]
Data port
RS-232C USB LAN
Sub Port
RS-232C xoo
USB o
xo
LAN o o
x
Condition
Interface
Keypad connection Keypad disconnection
Data Port Sub Port Data Port Sub Port
RS-232C x x o o
USB x o o o
LAN x o o o
NONE x x x o