Section 3: Operation and Configuration
HR2 Series Operator Manual Page 3-57
3.16 SERVICE MODE (Cont’d)
1. When SENSOR LEVEL is selected, press the FEED button repeatedly will switch to the next setting
options as shown above. To return to the previous setting option, press LINE button. To return to SERVICE
MODE screen, press and hold LINE button.
2. When the desired setting option is displayed, press <, > arrow buttons to select the item or + / - buttons to
set the value and then press FEED button to save the setting.
SENSOR LEVEL MODE
Menu Description
Displaying the current level of gap sensor on the upper part of the display. The
number beside GAP shows the position of the GAP sensor, ascending from the
center to the right of the printer. Adjust the sensor level offset with + / - buttons.
This offset determined how soon the sensor responds to an oncoming gap.
The adjustment range is between 0 and 99 and is shown on the bottom line of
the display. The default setting is 50.
Press <, > arrow buttons to save the setting and switch to slice level display.
The slice level is calculated automatically and displayed on the bottom line.
Adjust the slice level by pressing + / - buttons. The input range is between 0.0
and 3.2. (adjustable in increments of 0.1)
Note
: The slice level is automatically set by firmware when the value is set to 0.0.
Press FEED button to save the setting and proceed to the next screen.
Displaying the current level of I-Mark sensor on the upper part of the display.
Adjust the sensor level offset with + / - buttons. This offset determined how
soon the sensor responds to an oncoming I-Mark. The adjustment range is
between 0 and 99 and is shown on the bottom line of the display. The default
setting is 50.
Press <, > arrow buttons to save the setting and switch to slice level display.
The slice level is calculated automatically and displayed on the bottom line.
Adjust the slice level by pressing + / - buttons. The input range is between 0.0
and 3.2. (adjustable in increments of 0.1)
Note
: The slice level is automatically set by firmware when the value is set to 0.0.
Press FEED button to save the setting and proceed to the next screen.
Displaying the current state of dispensing sensor.
[0] indicates no label
[1] indicates with label.
Displaying the current state of rewinding sensor.
[1] indicates the rewinder for the liner (backing paper) is full.
+
-
+
-
+
-
+
-
