Setting Description
Perform complete startup
(→2170)
If the following situation exists:
• Initial startup of the motor
• Performance of extensive changes (e.g. motor
or encoder change)
Perform partial startup
(→2173)
When startup settings of the motor values (e.g.
supply or motor voltage) or download values of the
drive parameters are modified.
Optimizing a speed controller
(→2173)
When speed controller already in operation is op-
timized by changing the download values of the
drive parameters.
Perform complete startup
Perform a complete startup to make all the necessary settings for operation of the
drive.
Proceed as follows:
1. Select a motor configuration.
9007201326609675
Setting Description
Single motor
The device controls a single motor.
• The optimal operating mode for operating motors
from SEW‑EURODRIVE is "vector controlled/
servo".
• If operation of a non-SEW motor with vector con-
trol does not achieve a satisfactory result, you
can select the operating mode "Standard (V/f)".
Several identical motors
The device controls several motors of the same
power rating. Select whether:
• the motors are mechanically rigid
• the motors are not/are loosely coupled