13
Parameter setting
"PFA-..." power section parameter overview
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
187
3.. Motor parameters
32./33. Motor adjustment1/2
No. Name Range/factory setting
322/332 IxR adjustment1/2 0–100%
323/333 Premagnetization time1/2 0–2s
324/334 Slip compensation1/2 0–500min
-1
3.. Motor parameters
34. Motor protection
No. Name Range/factory setting
340/342 Motor protection1/2 Off
341/343 Cooling type1/2 Fan cooled
344 Motor protection interval 0.1–4–20s
345/346 I
N
-U
L
monitoring1/2 0.1–500A
3.. Motor parameters
35. Direction of motor rotation
No. Name Range/factory setting
350/351 Direction of rotation reversal1/2 Off
5.. Monitoring functions
50. Speed monitoring
No. Name Range/factory setting
500/502 Speed monitoring1/2 Motor/regenerative
501/503 Delay time1/2 0–1–10s
504 Encoder monitoring motor Off
505 Distance encoder monitoring Off
5.. Monitoring functions
52. Mains OFF monitoring
No. Name Range/factory setting
520 Mains OFF response time 0–5s
521 Mains OFF response Controller inhibit
522 Phase failure monitoring On
5.. Monitoring functions
53. Motor temperature protection
No. Name Range/factory setting
530 Sensor type1 No sensor
531 Sensor type2 No sensor
5.. Monitoring functions
54. Gear unit/motor monitoring
No. Name Range/factory setting
540 Response to vibration/warning Display error
541 Response to vibration/error Rapid stop/Warning
542 Response to oil aging/warning Display error
543 Response to oil aging/error Display error
544 Response oil aging/over-temperature Display error
545 Response oil aging/ready signal Display error
549 Response to brake wear Display error
5.. Monitoring functions
56. Ex‑e motor current limitation
No. Name Range/factory setting
560 Ex‑e motor current limit Off
561 Frequency A 0–5–60Hz
562 Current limit A 0–50–150%
563 Frequency B 0–10–104Hz
564 Current limit B 0–80–200%