5.. Monitoring functions
56. Ex‑e motor current limitation
No. Name Range/factory setting
565 Frequency C 0–25–104Hz
566 Current limit C 0–100–200%
6.. Terminal assignment
60. Digital inputs of basic device
No. Name Range/factory setting
601 Digital input DI02 No function
602 Digital input DI03 No function
603 Digital input DI04 No function
604 Digital input DI05 No function
7.. Control functions
70. Operating modes
No. Name Range/factory setting
700/701 Operating mode 1/2 VFC
702 Motor category Rotatory
7.. Control functions
71. Standstill current
No. Name Range/factory setting
710/711 Standstill current 1/2 0–50%I
N
(Motor)
7.. Control functions
72. Setpoint stop function
No. Name Range/factory setting
720/723 Setpoint stop function 1/2 Off
721/724 Stop setpoint 1/2 0–30–500min
-1
722/725 Start offset1/2 0–30–500min
-1
7.. Control functions
73. Brake function
No. Name Range/factory setting
730/733 Brake function1/2 On
731/734 Brake release time1/2 0 – 2s
732/735 Brake application time1/2 0–2s
7.. Control functions
74. Speed skip function
No. Name Range/factory setting
740/742 Skip window center1/2 0–1500–6000min
-1
741/743 Skip width1/2 0–300min
-1
7.. Control functions
77. Energy-saving function
No. Name Range/factory setting
770 Energy-saving function Off
8.. Device functions
80. Setup
No. Name Range/factory setting
802 Factory setting No
803 Parameter lock Off
804 Reset of statistic data No action
8.. Device functions
82. Braking operation
No. Name Range/factory setting
820/821 4-quadrant operation1/2 On
16998413/EN – 12/2016