Parameter setting
"PFA-..." power section parameter overview
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
189
8.. Device functions
83. Error responses
No. Name Range/factory setting
830 Response to "external error" Emergency stop/malfunction
832 Response to "motor overload" Emergency stop/malfunction
834 Response to "lag error" Emergency stop/malfunction
835 Response to "TF signal" No response
836 Response to "timeout SBus1" Emergency stop/malfunction
838 Response to "SW limit switch" Emergency stop/malfunction
839 Response to 'positioning interruption' No response
8.. Device functions
84. Reset behavior
No. Name Range/factory setting
840 Manual reset No
841 Auto reset No
842 Restart time 1–3–30s
8.. Device functions
85. Scaling actual speed value
No. Name Range/factory setting
850 Scaling factor numerator 1–65535
851 Scaling factor denominator 1–65535
852 User unit 1/min
8.. Device functions
86. Modulation
No. Name Range/factory setting
860/861 PWM frequency1/2 4/8/12/16kHz
862/863 PWMfix1/2 Off
864 PWM frequency CFC 4/8/16kHz
8.. Device functions
87. Process data description
No. Name Range/factory setting
870 Setpoint descriptionPO1 Control word1
872 Setpoint descriptionPO2 Setpoint speed
872 Setpoint descriptionPO3 Ramp
873 Actual value descriptionPI1 Status word1
874 Actual value descriptionPI2 Actual speed
875 Actual value descriptionPI3 Output current
876 PO data enable Yes
9.. IPOS parameters
90. IPOS reference travel
No. Name Range/factory setting
900 Reference offset -(2
31
-1)–0–(2
31
-1)
901 Reference speed 1 0–200–6000min
-1
902 Reference speed 2 0–50–6000min
-1
903 Reference travel type [0] Left zero pulse
904 Reference travel to zero pulse Yes
905 Hiperface offset (motor) -(2
31
-1)–(2
31
-1)
906 Cam distance Display value
9.. IPOS parameters
91. IPOS travel parameters
No. Name Range/factory setting
910 Gain X controller 0.1–0.5–32
911 Positioning ramp1 0.01–1–20s