Parameter setting
Parameter descriptions
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
229
P87. Process data description
P870/P871/P872 Setpoint description PO1/PO2/PO3
Defines the content of the process output data words PO1/PO2/PO3. The power sec-
tion "PFA-..." can only allocate the corresponding setpoints according to this specifica-
tion.
Specifically, the parameters are:
Parameter Factory setting
P870 Setpoint description PO1 Control word1
P871 Setpoint description PO2 Setpoint speed
P872 Setpoint descriptionPO3 Ramp
The process output data words can be allocated as follows:
Assignment Description
No function The content of the process output word is ignored.
Setpoint speed Setpoint speed in min
-1
Set current Current setpoint input with torque control
Set position low Setpoint position low word
Set position high Setpoint position high word
Max. speed Maximum system speed (→2202)
Max. current Current limitation in % of I
N
of the device (→2203)
Slip speed Slip compensation (→2205)
Ramp Ramp time for setpoint selection
Control word1 Control signals for start/stop, etc.
Control word2 Control signals for start/stop, etc.
Setpoint
speed[%]
Setpoint speed specification in % of n
max
IPOS PO data
Specification of a 16-bit encoded value for an IPOS
PLUS®
applica-
tion module
For more detailed information, refer to the "Fieldbus Device Profile with List of Para-
meters" manual.