14
Service
List of power section errors
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
253
Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
31 TF/TH trig-
ger
No re-
sponse (P)
0 Thermal motor
protection error
Motor too hot, TF/
TH has triggered
TF/TH of the motor
not connected or
connected incor-
rectly
Device connection
and TF/TH con-
nection on motor
interrupted
Let motor cool off
and reset error
Check connec-
tions/link between
device and TF/TH
Set P835 to "No
response"
32 IPOS
®
in-
dex over-
flow
Emergency
stop
0 IPOS
plus®
program
faulty
Programming prin-
ciples violated leading
to system internal
stack overflow
Reload the application
module
34 Ramp
timeout
Immediate
stop
0 Timeout rapid
stop ramp
Downward ramps
timeout, e.g. due to
overload.
Extend the down-
wards ramps
Eliminate overload
35 Operating
mode
Immediate
stop
0 Operating mode
not available
Operating mode not
defined or defined in-
correctly
Use P700/P701 to set
correct operating
mode
1 Incorrect assign-
ment of operating
mode and hard-
ware
37 System
watchdog
Immediate
stop
0 "System watch-
dog overflow"
error
Error while executing
system software
Contact
SEW‑EURODRIVE
Service
38 System
software
Immediate
stop
0 "System soft-
ware" error
System error Contact
SEW‑EURODRIVE
Service
39 Reference
travel
Immediate
stop (P)
0 "Reference
travel" error
The reference cam
is missing or does
not switch
Limit switches are
connected incor-
rectly
Reference travel
type was changed
during reference
travel
Check reference
cams
Check limit switch
connection
Check reference
travel type setting
and required para-
meters
40 Boot syn-
chroniza-
tion
Immediate
stop
0 Timeout during
boot synchroniza-
tion
Error during boot syn-
chronization between
inverter and option.
Contact
SEW‑EURODRIVE
Service if the error re-
occurs
41 Watchdog
option
Immediate
stop
0 Error – Watchdog
timer from/to op-
tion.
Error in communica-
tion between system
software and option
software
Contact
SEW‑EURODRIVE
Service
16998413/EN – 12/2016

Table of Contents