Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
42 Lag error Immediate
stop (P)
0 Positioning lag
error
Rotary encoder
connected incor-
rectly
Acceleration ramps
too short
P component of
positioning control-
ler too small
Incorrectly set
speed controller
parameters
Value of lag error
tolerance too small
Check rotary en-
coder connection
Extend ramps
Set P component
to higher value
Set speed control-
ler parameters
again
Increase lag error
tolerance
Check wiring of en-
coder, motor and
line phase
Make sure mech-
anical parts can
move freely, check
whether they are
blocked
43 Manual
mode
timeout
Immediate
stop (P)
0 Manual mode
timeout
Manual mode not
completed correctly.
a) Activate manual
mode.
ð Manual mode was
completed cor-
rectly.
44 Device util-
ization
Immediate
stop
0 Device utilization
error
Device utilization (IxT
value) > 125%
Decrease power
output
Extend ramps
If suggested ac-
tions are not pos-
sible, use a larger
inverter
Reduce load
8 U
L
monitoring
error
45 Initializa-
tion
Immediate
stop
0 General error
during initializa-
tion
No parameters set for
EEPROM in power
section, or parameters
set incorrectly
Restore delivery state
(P802)
If error cannot be reset
afterwards, contact
SEW‑EURODRIVE
Service
3 Data bus error
during RAM
check
6 CPU clock error
7 Error in the cur-
rent detection
10 Error when set-
ting flash protec-
tion
11 Data bus error
during RAM
check