Code Meaning Response
(P)
Sub-
code
Meaning Possible cause Measure
47 System
bus 1
timeout
Rapid stop
(P)
0 Timeout system
bus CAN1
Error during commu-
nication via system
bus 1.
Check system bus
connection
57 TTL en-
coder
Immediate
stop
1 TTL encoder:
Wire break
512 TTL encoder: Er-
ror in amplitude
control
541 TTL encoder: In-
correctly set nu-
merator/denomin-
ator values
Set the correct system
numerator/denomin-
ator values.
16385 TTL distance en-
coder: Wire break
16896 TTL distance en-
coder: Error in
amplitude control
16898 TTL distance en-
coder: Incorrectly
set numerator/de-
nominator values
Set the correct system
numerator/denomin-
ator values.
58 Sin/cos en-
coder
Immediate
stop
1 Sin/cos encoder:
Wire break
512 Sin/cos encoder:
Error in amplitude
control
514 Sin/cos encoder:
Track signal error
515 Sin/cos encoder:
Incorrectly set
numerator/de-
nominator values
Set the correct system
numerator/denomin-
ator values.
16385 Sin/cos distance
encoder: Wire
break
16896 Sin/cos distance
encoder: Error in
amplitude control
16898 Sin/cos distance
encoder: Track
signal error
16899 Sin/cos distance
encoder: Incor-
rectly set numer-
ator/denominator
values
Set the correct system
numerator/denomin-
ator values.