Configuration and startup of EtherNet/IP™
Project planning examples
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
60
11. Save the project and transfer it to the PLC.
12. Enter the following controller tags values:
19132375179
Controller tag Value
WriteParameterStart 1
WriteParameterRequest.Index Index of the parameter to be described.
WriteParameterRequest.Data Value to be written in the parameter.
WriteParameter_Request.SubAddress 1 20
WriteParameter_Request.SubChannel 1 3
WriteParameter_Request.SubAddress 2 0
WriteParameter_Request.SubChannel 2 0
13. Switch to RUN mode of the PLC.
ð The write request is executed once.
ð If the write request is answered, the controller tag "WriteParameterRe-
sponse.Index" displays the written index. The controller tag "WriteParamet-
erResponse.Data" contains the written data.
ð In this example, the parameter P302 maximum speed is set to 3000min
-1
.
16998413/EN – 12/2016