7
Ethernet Industrial Protocol (EtherNet/IP™)
CIP object directory
Manual – MOVIPRO
®
with EtherNet/IP™ or Modbus/TCP Fieldbus Interface
82
7.4.6 Vardata object
This manufacturer-specific object allows for engineering with software tools from
SEW‑EURODRIVE.
Class code: 64
hex
Class
None of the class attributes are supported.
Instance 1
The following table provides an overview of instance 1 of the Vardata object:
Attrib-
ute
Ac-
cess
Name Data type Default value
hex
Description
1 Get Data ARRAY OF SINT
2 Get Size UINT 00F2 Maximum data length in bytes
Supported services
The following table shows the services supported by the Vardata object:
Service Code
hex
Service Name Instance attribute 1 Instance attribute 2
0E Get_Attribute_Single X X
32 Vardata (custom) X
The standardized service "Get_Attribute_Single" (Service Code 0x0E) delivers a data
stream with the maximum data length (attribute 2) when instance attribute 1 is ac-
cessed. The data content is filled with zeros. If a data stream is added to the request
telegram ("Service Type Custom"), this data is returned in a mirrored form (Vardata
test mode).
The Vardata service (service code 0x32) is manufacturer-specific. Request and re-
sponse of this service have the same telegram structure. The telegram contains rout-
ing information, the data length of the Vardata user data telegram and the actual
Vardata layer -7 telegram. The data length of the Vardata layer -7 telegram is variable.
The following table shows the complete telegram structure.
Name Data type
Subaddress 1 BYTE
Subchannel 1 BYTE
Subaddress 2 BYTE
Subchannel 2 BYTE
Data Len Low BYTE
Data Len High BYTE
Reserved BYTE
Reserved BYTE
FC BYTE
Vardata Array of BYTE
16998413/EN – 12/2016