Chapter 4 Operating instructions
S300
30 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010948/YY96/2016-02-17
Subject to change without notice
Configurable functions
The table below shows the differences between the functions of the S300 variants in the
compatibility mode.
Functions
Standard
Advanced
Professional
Expert
Application diagnostic output “Warning field
interrupted”
Application diagnostic output
“Error/contamination”
Application diagnostic output “Reset required”
External device monitoring (EDM)
Restart interlock/delay
Field sets comprising of protective field and one
warning field
1 2 4 8/4
4)
Programmable monitoring cases in standalone
mode
1 2 4 8
Velocity routing using a Flexi Soft safety controller
The user interface of the CDS in compatibility mode corresponds to the user interface of
CDS version 3.6.6.
The related operating instructions delivered with the device are to be used for older
devices (see 1.3 “Scope” on page 7).
4)
8 field sets at angular resolution 1.0°; 4 field sets at angular resolution 0.5°.
Tab.
6
:
Funct
ions of the
S300 variants in the
compatibility mode
Notes

Table of Contents

Other manuals for SICK S300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 and is the answer not in the manual?

SICK S300 Specifications

General IconGeneral
Protection ClassIP65
Resolution30 mm
InterfaceRS-422, Ethernet
Power Supply24 V DC
Operating Temperature0 °C ... +50 °C