1PosInc/Analog
4.6 Functions of the 1PosInc/Analog
ET 200S Positioning
126 Operating Instructions, 05/2007, A5E00124871-04
Parameters: Define the variables that depend on the drive, axis, and encoder uniquely in the
parameters.
3DUDPHWHUV
&RQWUROSURJUDP
XVLQJ02'(VDQG-2%V
$[LVGULYH
HQFRGHU
&RQWUROVLJQDOV
)HHGEDFNVLJQDOV
)XQFWLRQVRIWKH
3RV,QF$QDORJ
(QFRGHUVLJQDOV
$QDORJRXWSXW4
DQGGLJLWDORXWSXW
287
',',',
Figure 4-4 How the 1PosInc/Analog Works
Interfaces to the Control Program and the Axis
To execute the function, the 1PosInc/Analog has digital inputs as an interface to the axis,
encoder signals for the connection of an incremental encoder, and an analog and a digital
output to control the drive.
You can modify and monitor the types of motion (MODEs) and other functions (JOBs) with
your control program using control signals and feedback signals.
See also
Parameter List (Page 178)