2.5.4 Setting the Base Frequency
Introduction
Through parameter assignment, the 1STEP 5V/204kHz permits the base frequency to be set
in steps.
The base frequency sets the range for the start-stop frequency, the output frequency, and
the acceleration.
Procedure
1. Depending on the priority of your request, select one of the three columns from the
following table:
Range for the start-stop frequency F
ss
,
for example, for starting and stopping as soon as possible
Range for the output frequency F
a
,
for example, for a velocity setting that is as precise as possible
Range for the maximum acceleration a,
for example, for the fastest possible positioning operations
2. Use the table to determine the base frequency F
b
.
To optimize the base frequency F
b
proceed as follows:
3. Check whether the other corresponding values meet your requirements. If necessary,
select another base frequency F
b
, which meets your requirements better.
4. Define the multipliers required to set the output frequency F
a
, the acceleration/delay a,
and the start-stop frequency F
ss
.