Example 2: Reference Point Run with Minus Limit Switch
Start position: between the minus limit switch and the plus limit switch
Start direction: Minus
Reference signal: Reference switch
Reference switch: Minus limit switch
6<1&
/LPLWVZLWFKPLQXV
5DSLGIHHG
&UHHSIHHG
6WDUWSRVLWLRQ
Figure 3-11 Reference Point Run with Minus Limit Switch
You can also carry out synchronization at the limit switch with the following zero mark.
If the start position is at the limit switch, the 1PosInc/Digital controls the drive directly in
creep feed in the referencing direction.