1PosSSI/Digital
5.2 Brief Introduction to Commissioning the 1PosSSI/Digital
ET 200S Positioning
190 Operating Instructions, 05/2007, A5E00124871-04
5.2 Brief Introduction to Commissioning the 1PosSSI/Digital
Introduction
Using the example of inching mode, this brief introduction shows you a functioning
application in which you get to know and check the hardware and software involved in a
positioning operation of your 1PosSSI/Digital.
Prerequisites for the Example
The following prerequisites must be fulfilled:
You must have put an ET 200S station on an S7 station with a DP master into operation.
You must have:
A TM-E30S44-01 terminal module (6ES7 193-4CG20-0AA0 or
6ES7 193-4CG30-0AA0)
A 1PosSSI/Digital
An SSl encoder
A drive with power control (e.g. a pole-changing motor with contactor switching)
A 24 VDC power supply
The necessary wiring material