1PosInc/Analog
4.6 Functions of the 1PosInc/Analog
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
127
Principle
What You Do Response of the 1PosInc/Analog
Provide the control interface with data depending on the
MODE.
Check the POS_ACK feedback bit is at 0
Switch the START control bit from 0 to 1 The 1PosInc/Analog sets the feedback bit POS_ACK = 1
and POS_DONE = 0.
You can tell by this that the start has been detected by
1PosInc/Analog and when POS_ERR = 0, the MODE is
executed.
The MODE is not executed when POS_ERR = 1.
Switch the START control bit from 1 to 0 The 1PosInc/Analog sets the feedback bit POS_ACK = 0
In the case of a stop, the reference point run, and absolute
and relative positioning, the 1PosInc/Analog sets the
feedback bit POS_DONE = 1 when the MODE is completed
without errors.
When POS_ERR = 1 the MODE is terminated with an error.
Only when POS_ACK=0 can you start a new MODE.
If you start when a MODE is running, the 1PosInc/Analog takes on the new motion and executes a change of direction, if
necessary.
326B(55
326B'21(
326B$&.
67$57
Figure 4-5 Control and Feedback Signals with MODEs