4.6.13 Changing the Voltage for Rapid Feed (JOB 5)
Definition
By changing the voltage for rapid feed (JOB 5) you can adjust the speed for rapid feed.
Supply the control interface with the new rapid feed voltage and activate JOB 5.
You can set a voltage between 0 V and 11.7589 V (including overrange) in S7 analog value
format (you will find a detailed explanation in the
Distributed I/O Device
manual).
The 1PosInc/Analog accepts the preset voltage. When the drive runs in rapid feed, it
accelerates/decelerates at the set acceleration/deceleration rate to the new rapid feed
voltage. The voltage remains valid until the parameter assignment of the 1PosInc/Analog is
changed.
Effect on the MODEs
MODE What Happens
Search for Reference When the drive runs in rapid feed, it accelerates/decelerates at the set
acceleration/deceleration rate to the new rapid feed voltage.
Inching -
Absolute Positioning
Relative Positioning
When the drive runs in rapid feed, it accelerates/decelerates at the set
acceleration/deceleration rate to the new rapid feed voltage.
Control Signals: Changing the Voltage for Rapid Feed
Address Assignment
Bits 4.7 to 4.4 :
7 6 5 4 Bit
0 1 0 1
JOB 5 = Change the voltage for rapid
feed
Byte 4
Bit 0: JOB_REQ
Bytes 5 to 7 Voltage for rapid feed
0 to 32 511 in S7 analog value format
Feedback Signals: Voltage for rapid feed
Address Assignment
Byte 4 Bit 1: JOB_ERR
Bit 0: JOB_ACK