1PosInc/Analog
4.6 Functions of the 1PosInc/Analog
ET 200S Positioning
158 Operating Instructions, 05/2007, A5E00124871-04
Voltage for Rapid Feed: Causes of Errors for JOB_ERR
Error Number Meaning What to Do
40 Voltage setting
Rapid feed speed > 32 511
See also
CPU/Master Stop and RESET State (Page 176)