EasyManua.ls Logo

Siemens SIMATIC ET 200S - Table 7-4 Causes of Errors for JOB_ERR

Siemens SIMATIC ET 200S
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1PosUniversal/Digital
7.6 Functions of the 1PosU
ET 200S Positioning
366 Operating Instructions, 05/2007, A5E00124871-04
Causes of Errors for JOB_ERR
Table 7-4 Causes of Errors for JOB_ERR
Error Number Meaning Remedy
21 JOB unknown or impermissible Permissible JOBs are:
JOB 0
JOB 1
JOB 2 (only possible at SSI encoders)
JOB 3
JOB 4
JOB 9 (not possible at SSI encoders or in
dosing operation)
JOB 10
JOB 11 (not possible in dosing operation)
JOB 15
23 ERR_ENCODER is displayed Check the encoder wiring
26 JOB 2 (move encoder range) cannot be initiated
because there is an active run
29 Evaluating the Reference Signal: Reference point
coordinates ≥ end of rotary axis
34 Setting an Actual Value: Actual value coordinates
≥ encoder range
35 Display current values: Selection unknown
36 Latch Function: Edge selection unknown
37 Display current values: JOB 15 cannot be
activated with the latch function running.
38 Monitoring of the direction of rotation
Path difference > 65 535

Table of Contents

Other manuals for Siemens SIMATIC ET 200S

Related product manuals