1PosSSI/Digital
5.6 Functions of the 1PosSSI/Digital
ET 200S Positioning
232 Operating Instructions, 05/2007, A5E00124871-04
Causes of Errors for JOB_ERR
Table 5-2 Causes of Errors for JOB_ERR
Error Number Meaning Remedy
21 JOB unknown Permissible JOBs are:
• JOB 0
• JOB 1
• JOB 3
• JOB 4
• JOB 9
• JOB 10
• JOB 11
• JOB 15
23 ERR_ENCODER is displayed Check the encoder wiring
26 JOB 2 (move encoder range) cannot be initiated
because there is an active run
33 With JOB 2: Offset not in encoder range
34 Setting an Actual Value: Actual value coordinates
≥ encoder range
35 Display current values: Selection unknown
36 Latch Function: Edge selection unknown
37 Display current values: JOB 15 cannot be
activated with the latch function running.
38 Monitoring of the direction of rotation
Path difference > 65 535